Check Voltage Step

 
Check Voltage Step
 
This Step checks if the battery voltage has ever dropped below a specified value.  If the voltage drops below 2.0 volts during normal use, it is probably time to retire the PIM.
 
1

Voltage Limit

This specifies the voltage level to check for.
2

No button

Pressing this button shows you the Steps that will be executed if the voltage stayed ABOVE or EQUAL to the specified value.  This defaults to simply continuing the Mission.  You may add Steps at this point if you like.
3

Yes button

Pressing this button shows you the Steps that will be executed if the voltage fell BELOW the specified value.  This defaults to Terminating the Mission with a status of "Failed".  You may add or delete Steps at this point if you like.